CycloComputer Update Manual

This manual is related to the update of the Cyclocomputer for Windows PCs. The firmware update of the SGX-CA900/SGX-CA500 (hereafter "the Cyclocomputer" uses the dedicated PC Aplication "Pioneer Cycle Cloud Connect". Firstly it is necessary to install Pioneer Cycle Cloud Connect on your PC. The following steps are required to update the CycloComputer:

Refer to the following for details of each step.

  • Depending on the Security settings of your browser there may be warning messages shown when downloading warning of possible security problems due to the download. These will have no effect on the update operation and should be ignored.

  • If the device is logging, stop logging and save the log data before the update.

Install Pioneer Cycle Cloud Connect

Outline

Install Pioneer Cycle Cloud Connect.

Explanation of Screen

Start

http://pioneer-cyclesports.com/us-en/support/products/

Download the executable file from the above URL.

Double click the downloaded file to execute it.

If the User Account Dialog box is shown, press "YES".

Language Selection

Select the language to be used during installation and then press "OK".

Setup Wizard

Click on "NEXT".

Please read the Terms of Service, select the "I Agree" box, then click on "NEXT".

To install the software click on "INSTALL".

Device Driver Installation Wizard

During the installation of Pioneer Cycle Cloud Connect, the Device Driver will be installed. Please follow the instructions shown for Driver Installation.

Now Installing Driver. Please click on "NEXT".

If the Windows Security Dialog box is shown, please click on "Install".

If the Driver is installed correctly, the Installation Wizard will show an "Installation Complete" dialog Box.
Please click on "Finish".

If Microsoft .NET Framework 4 is not installed,

If Microsoft .NET Framework 4 is not installed on your computer the Microsoft .NET Framework 4 Setup is shown. Please select"I AGREE" then click on "INSTALL".

After the Install Progress is shown, the Setup Complete Window is shown. Please click on "FINISH" to complete the installation. A Restart of the computer may be necessary.

Cycle Cloud Connect Installation is now complete.
Please select "Run Pioneer Cycle CloudConnect.exe" and click on "CLOSE" to close the Dialog Box.

Update the Firmware of the SGX-CA900

Outline

Start the Firmware Manager and update the firmware of the CycloComputer

Please carry out the following operations on the CycloComputer.

Start up Update Mode on the CycloComputer

  1. If USB is connected, first disconnect the USB connector.
  2. The SETTINGS menu can be selected by pressing "SETTINGS" on the Home Screen.
  3. Please tap on "SYSTEM" then "FIRMWARE UPDATE". Messages will be shown regarding the Backup of Settings and Firmware Update.
  4. Please tap on [OK]. Backup data will be generated automatically, then Update Mode will activate.
  5. Confirm that the CycloComputer Screen is illuminated all in white.
  6. Connect the CycloComputer to the PC via USB.

If the screen is flashing, then the battery level is insufficient. Please charge sufficiently before continuing.

Please confirm that the CycloComputer is in Update Mode, then perform the following operations in Pioneer Cycle Cloud Connect.

Pioneer Cycle Cloud Connect Operation

Method of Operation

  1. Click on the Pioneer Cycle Cloud Connect Icon in the Menu Bar, select "Actiate Firmware Manager"
  2. Connect the CycloComputer, which should be in Update Mode, to the PC via USB.
  3. Follow the instructions given by the Wizard.

Firmware Update can take 20-30 minutes in a FTTH environment.

Explanation of Screen

Start

Please confirm that the PC is connected to the Internet, and the CycloComputer is connected in Update Mode to the PC.

Select "NEXT" to proceed to the Firmware Selection Screen.
Selecting "CANCEL" will cause the application to terminate.

If multiple Cyclocomputers are detected

a list is shown of the Cyclocomputers that are capable of being updated. Please select the correct Cyclocomputer

SGX-CA900 Update Start

Select "NEXT"

If the Serial Number Registration Screen is shown

Please input the tewelve digit serial number shown on the CycloComputer and press "NEXT". The serial number is the twelve digit number/letter combination shown in the "S/N" Section on the back of the CycloComputer. If the Serial Number is input correctly, the Select Firmware Screen is shown.
Selecting "CANCEL" will cause the application to terminate.

Firmware Selection

Selection of Firmware

Please select the version of the firmware you wish to update. The Update History of that version will be shown.

Current Firmware Version

The Firmware Version of the currently connected CycloComputer is shown.

Selecting "NEXT" causes the Software License Agreement to be shown.
Selecting "CANCEL" will cause the application to terminate.

Software License Agreement

The Software License Agreement for the Firmware is shown. Select "AGREE" to accept to the agreement.

Selecting "NEXT" causes the Firmware Update Confirmation Screen to be shown.
Select "RETURN" to return to the Select Firmware Screen.
Selecting "CANCEL" will cause the application to terminate.

Update Confirmation

Please confirm the Current Version and Update Version of the firmware.

Select "NEXT" to proceed to the Version Update Screen, wher the Update Operation will begin.
Select "RETURN" to return to the Software License Agreement Screen.
Selecting "CANCEL" will cause the application to terminate.

Firmware Update

The progress of the Version Update of the CycloComputer is shown. Once the Update is complete, the "NEXT" button will become active.

Select "NEXT" to proceed to the Update Result Screen.

Cyclocomputer Restart

Press the START/STOP button for five seconds with the USB cable still attached. [NEXT] will become active.

Update Result

The Result of the Update Operation is shown. Follow the instructions in the Dialog Window to carry out the following operations on the CycloComputer.

Please perform the following operations on the CycloComputer.
  1. With the CycloComputer still connected to the PC via USB, press the START/STOP button for five seconds or more. The CycloComputer will restart.
  2. The CycloComputer will show the Initial Settings Screen, so please select the Language. The Firmware Update will then continue.
  3. Once the CycloComputer shows the Disconnect Message, please disconnect the USB cable from the CycloComputer.
  4. The CycloComputer will show a message confirming the restoration of settings. Please select "YES".
  5. Once the Firmware Update is complete, the CycloComputer will automatically turn off.
The Update is now complete. Click on "FINISH" in the Application Screen to terminate the Firmware Manager. To repeat the Update procedure, return to Step 2. "Update the Firmware of the SGX-CA900".

Update the Firmware of the SGX-CA500

Outline

Start the Firmware Manager and update the firmware of the CycloComputer

Please carry out the following operations on the CycloComputer.

Start up Update Mode on the CycloComputer

  1. If USB is connected, first disconnect the USB connector.
  2. The SETTINGS menu can be selected by pressing "SETTINGS" on the Home Screen.
  3. Please tap on "SYSTEM" then "FIRMWARE UPDATE". Messages will be shown regarding the Backup of Settings and Firmware Update.
  4. Please tap on [CycleCloudConnect]. Backup data will be generated automatically, then Update Mode will activate.
  5. Confirm that the CycloComputer Screen is illuminated all in white.
  6. Connect the CycloComputer to the PC via USB.

If the screen is flashing, then the battery level is insufficient. Please charge sufficiently before continuing.

Please confirm that the CycloComputer is in Update Mode, then perform the following operations in Pioneer Cycle Cloud Connect.

Pioneer Cycle Cloud Connect Operation

Method of Operation

  1. Click on the Pioneer Cycle Cloud Connect Icon in the Menu Bar, select "Actiate Firmware Manager"
  2. Connect the CycloComputer, which should be in Update Mode, to the PC via USB.
  3. Follow the instructions given by the Wizard.

Explanation of Screen

Start

Please confirm that the PC is connected to the Internet, and the CycloComputer is connected in Update Mode to the PC.

Select "NEXT" to proceed to the Firmware Selection Screen.
Selecting "CANCEL" will cause the application to terminate.

If multiple Cyclocomputers are detected

A list is shown of the Cyclocomputers that are capable of being updated. Please select the correct Cyclocomputer

SGX-CA500 Update Start

Select "NEXT"

Firmware Selection

Selection of Firmware

Please select the version of the firmware you wish to update. The Update History of that version will be shown.

Current Firmware Version

The Firmware Version of the currently connected CycloComputer is shown.

Selecting "NEXT" causes the Software License Agreement to be shown.
Selecting "CANCEL" will cause the application to terminate.

Software License Agreement

The Software License Agreement for the Firmware is shown. Select "AGREE" to accept to the agreement.

Selecting "NEXT" causes the Firmware Update Confirmation Screen to be shown.
Select "RETURN" to return to the Select Firmware Screen.
Selecting "CANCEL" will cause the application to terminate.

Update Confirmation

Please confirm the Current Version and Update Version of the firmware.

Select "NEXT" to proceed to the Version Update Screen, wher the Update Operation will begin.
Select "RETURN" to return to the Software License Agreement Screen.
Selecting "CANCEL" will cause the application to terminate.

Firmware Update

The progress of the Version Update of the CycloComputer is shown. Once the Update is complete, the "NEXT" button will become active.

Select "NEXT" to proceed to the Update Result Screen.

Update Result

The Result of the Update will be shown. Please disconnect the USB connection.

The Firmware Update of the SGX-CA500 will start now. The SGX-CA500 will automatically reboot after the update is complete.


Check the firmware version

Check the firmware version.
If the right most number of the firmware version is over 38, the update is now complete.

If the right most number of the firmware version is 37 or less, it is necessary to restore your setting data after firmware update completion. Follow the procedure described in "Restore the setting data".

※How to check the firmware version

Please carry out the following operations on the CycloComputer.


From the HOME screen, tap on the [Settings] icon - [System].



You will find the firmware version at the list.


Restore the setting data


If the right most number of the firmware version is 37 or less, please do the following. If it is over 38, you don't have to do the following.

Please carry out the following operations on the CycloComputer.

  1. Press a long push on the [MENU] button.
    When the Cyclocomputer restarts, the Cyclometer screen is shown, so press a long push on the [MENU] button to show the HOME screen.

  2. From the HOME screen, tap on the [Settings] icon.


  3. Tap on [System] - [Setting Manager] - [Restore]


  4. Tap on [OK]



    After a while, the Cyclocomputer will restart.




The Update is now complete.
Click on "FINISH" in the Application Screen to terminate the Firmware Manager.
To repeat the Update procedure, return to Step 2. "Update the Firmware of the SGX-CA500".